49 .         Method of collecting blood

        (1)         A blood sample is to be taken by a sample collector by venepuncture using the syringe.

        (2)         Before taking a blood sample the sample collector must cleanse the proposed site of the venepuncture using the mercury bichloride solution and cotton wool.

        (3)         After taking a blood sample — 

            (a)         the sample collector must discharge approximately half of the sample into each of the 2 sterile bottles;

            (b)         the sample collector must securely tighten the cap on each bottle and shake it thoroughly (by inverting it at least 20 times) to mix the contents;

            (c)         the sample collector and a police officer or employee must each complete and sign the relevant parts of the approved form;

            (d)         the sample collector must seal each of the sterile bottles in a separate package and seal it by fixing the form referred to in paragraph (c) over the opening of the package;

            (e)         the sample collector and police officer or employee must each sign his or her name over the sealed portion or flap of that package; and

            (f)         the sample collector must give one blood sample to the person from whom it was taken and the other sample to the police officer or employee.