• Specific Year
    Any

LOCAL GOVERNMENT (MANUFACTURED HOME ESTATES, CARAVAN PARKS, CAMPING GROUNDS AND MOVEABLE DWELLINGS) REGULATION 2005 - REG 57 Lighting and ventilation

LOCAL GOVERNMENT (MANUFACTURED HOME ESTATES, CARAVAN PARKS, CAMPING GROUNDS AND MOVEABLE DWELLINGS) REGULATION 2005 - REG 57

Lighting and ventilation

57 Lighting and ventilation

(1) A manufactured home must have adequate provision for light and ventilation.
(2) A habitable room must have natural lighting and natural ventilation provided by one or more windows to the outside air, or by one or more openings into an adjoining room, being windows or openings having--
(a) a total area of at least 10 per cent of the floor area of the room, and
(b) an area (being at least 5 per cent of the floor area of the room) that is capable of being opened.
(3) If any part of the natural lighting or natural ventilation for a habitable room is provided by one or more openings into an adjoining room, the adjoining room must have natural lighting and ventilation provided by one or more windows that comply with subclause (2) in relation to the combined area of both rooms.