Electricity supply
30 Electricity supply
(1) A dwelling site must be supplied with electricity
from a reticulated electricity service by means of an electrical circuit
connected to a separate electricity meter.
(2) Any such electrical circuit
must be installed in accordance with the requirements of AS/NZS 3000:2000,
Electrical Installations (known as the Australian/New Zealand Wiring Rules) as
in force on 1 September 2005, except that the maximum capacity of the
electrical circuit supplying a dwelling site need not be greater than 32
amperes if the site is provided with gas, whether by means of a reticulated
gas service or by means of on-site gas containers.
(3) If a dwelling site is
provided with electricity otherwise than by way of direct connection to the
local electricity supply authority’s electricity main, the maximum amount
that may be charged for the supply of electricity during a particular period
is the amount that the standard retail electricity supplier for the relevant
district would have charged under a standard form customer supply contract for
that supply during that period.