• Specific Year
    Any

LOCAL GOVERNMENT (MANUFACTURED HOME ESTATES, CARAVAN PARKS, CAMPING GROUNDS AND MOVEABLE DWELLINGS) REGULATION 2005 - REG 159 Compliance plates

LOCAL GOVERNMENT (MANUFACTURED HOME ESTATES, CARAVAN PARKS, CAMPING GROUNDS AND MOVEABLE DWELLINGS) REGULATION 2005 - REG 159

Compliance plates

159 Compliance plates

(1) A compliance plate must be attached to an accessible part of each of the following structures--
(a) a relocatable home,
(b) an associated structure that forms part of a relocatable home,
(c) an associated structure that comprises a free-standing garage.
(2) A compliance plate must specify the following--
(a) the name of the manufacturer of the relocatable home or associated structure,
(b) the unique identification number for each major section of the relocatable home,
(c) the month and year during which the relocatable home or associated structure was constructed,
(d) the design gust wind speed for the relocatable home or associated structure,
(e) a statement to the effect that the relocatable home or associated structure complies with the requirements of this Division,
(f) the name of the practising structural engineer by whom the engineer's certificate has been issued in respect of the relocatable home,
(g) whether a relocatable home is intended for use as a park van or holiday van.
(3) A unique identification number must be permanently marked on each major section of the relocatable home.
(4) The Minister may, by order published in the Gazette, issue specifications for the design, construction, issue and registration of compliance plates for the purposes of this clause.
(5) A compliance plate must be designed, constructed, issued and registered in accordance with any specifications in force under this clause.