New South Wales Consolidated Regulations(Clauses 4 (2), 5 (1), 6 (1), 15 (2) and 18 (1))
The following are the relevant standards for ducted single phase airconditioners, ducted single phase heat pumps, three phase airconditioners and three phase heat pumps:
(a) AS/NZS 3823.1.1:1998, Performance of electrical appliances-Airconditioners and heat pumps, Part 1.1: Test Methods-Non-ducted airconditioners and heat pumps-Testing and rating for performance ,
(b) AS/NZS 3823.1.2:2001, Performance of electrical appliances-Airconditioners and heat pumps, Part 1.2: Test Methods-Ducted airconditioners and air-to-air heat pumps-Testing and rating for performance ,
(c) AS/NZS 3823.1.3:2005, Performance of electrical appliances-Airconditioners and heat pumps, Part 1.3: Water-source heat pumps-Water-to-air and brine-to-air heat pumps-Testing and rating of performance (ISO 13256-1, Ed. 01 (1998) MOD) ,
(d) AS/NZS 3823.2:2005, Performance of electrical appliances-Airconditioners and heat pumps, Part 2: Energy labelling and minimum energy performance standard (MEPS) requirements .
The following are the relevant standards for fluorescent lamp ballasts for use with International Lamp Coding System (ILCOS) lamp type FD (type T) lamps:
(a) AS/NZS 4783.1:2001, Performance of electrical lighting equipment-Ballasts for fluorescent lamps, Part 1: Method of measurement to determine energy consumption and performance of ballasts lamp circuits ,
(b) AS/NZS 4783.2:2002, Performance of electrical lighting equipment-Ballasts for fluorescent lamps, Part 2: Energy labelling and minimum energy performance standards requirements .
The following are the relevant standards for linear fluorescent lamps:
(a) AS/NZS 4782.1.2004, Double-capped fluorescent lamps-Performance specifications, Part 1: General (IEC 60081:2000, MOD) ,
(b) AS/NZS 4782.2.2004, Double-capped fluorescent lamps-Performance specifications, Part 2: Minimum Energy Performance Standard (MEPS) .
The following are the relevant standards for power transformers:
(a) AS 2735-1984, Dry-type power transformers ,
(b) AS 2374.1-1997, Power transformers, Part 1: General ,
(c) AS 2374.1.2-2003, Power transformers, Part 1.2: Minimum Energy Performance Standard (MEPS) requirements for distribution transformers .
The following are the relevant standards for refrigerated display cabinets:
(a) AS 1731.1-2003, Refrigerated display cabinets, Part 1: Terms and definitions ,
(b) AS 1731.2-2003, Refrigerated display cabinets, Part 2: General mechanical and physical requirements ,
(c) AS 1731.3-2003, Refrigerated display cabinets, Part 3: Linear dimensions, areas and volumes ,
(d) AS 1731.4-2003, Refrigerated display cabinets, Part 4: General test conditions ,
(e) AS 1731.5-2003, Refrigerated display cabinets, Part 5: Temperature test ,
(f) AS 1731.6-2003, Refrigerated display cabinets, Part 6: Classification according to temperatures ,
(g) AS 1731.9-2003, Refrigerated display cabinets, Part 9: Electrical energy consumption test ,
(h) AS 1731.12-2003, Refrigerated display cabinets, Part 12: Measurement of the heat extraction rate of the cabinets when the condensing unit is remote from the cabinet ,
(i) AS 1731.13-2003, Refrigerated display cabinets, Part 13: Test report ,
(j) AS 1731.14-2003, Refrigerated display cabinets, Part 14: Minimum energy performance standard (MEPS) requirements .
The relevant standard for three phase rotating electrical machines is AS/NZS 1359.5:2004, Rotating electrical machines-General requirements, Part 5: Three-phase cage induction motors-High efficiency and minimum energy performance standards requirements .
The following are the relevant standards for storage water heaters:
(a) AS/NZS 4692.1:2005, Electric water heaters, Part 1: Energy consumption, performance and general requirements ,
(b) AS/NZS 4692.2:2005, Electric water heaters, Part 2: Minimum Energy Performance Standard (MEPS) requirements and energy labelling .
The following are the relevant standards for external power supplies:
(a) AS/NZS 4665.1:2005, Performance of external power supplies, Part 1: Test method and energy performance mark ,
(b) AS/NZS 4665.2:2005, Performance of external power supplies, Part 2: Minimum energy performance standard (MEPS) requirements .
The following are the relevant standards for digital television set-top boxes:
(a) AS/NZS 62087:2004, Methods of measurement for the power consumption of audio, video and related equipment ,
(b) AS/NZS 62087.2.1:2008, Power consumption of audio, video and related equipment, Part 2.1: Minimum energy performance standards (MEPS) requirements for digital television set-top boxes .
The following are the relevant standards for commercial building chillers:
(a) AS/NZS 4776.1.1:2008, Liquid-chilling packages using the vapour compression cycle, Part 1.1: Method of rating and testing for performance-Rating ,
(b) AS/NZS 4776.1.2:2008, Liquid-chilling packages using the vapour compression cycle, Part 1.2: Method of rating and testing for performance-Testing ,
(c) AS/NZS 4776.2:2008, Liquid-chilling packages using the vapour compression cycle, Part 2: Minimum energy performance standard (MEPS) and compliance requirements .
The following are the relevant standards for close control airconditioners:
(a) AS/NZS 4965.1:2008, Performance of close control airconditioners, Part 1: Testing for rating ,
(b) AS/NZS 4965.2:2008, Performance of close control airconditioners, Part 2: Minimum energy performance standard (MEPS) requirements .
(1) The following are the relevant standards for prescribed incandescent lamps:(a) AS/NZS 4934.1(Int):2008, Incandescent lamps for general lighting service, Part 1: Test methods-Energy performance ,(b) AS/NZS 4934.2(Int):2008, Incandescent lamps for general lighting services, Part 2: Minimum Energy Performance Standards (MEPS) requirements .
(2) In this clause:
"prescribed incandescent lamp" means any of the following:(a) a general lighting service incandescent lamp,(b) an extra low voltage halogen non-reflector incandescent lamp.Note: This provision is subject to amendments to be made by the Energy and Utilities Administration Further Amendment (Minimum Energy Performance Standards) Regulation 2009 . These amendments commence on 1.10.2010 and 1.10.2012.
The following are the relevant standards for compact fluorescent non-reflector lamps:
(a) AS/NZS 4847.1(Int):2008, Self-ballasted lamps for general lighting services, Part 1: Test methods-Energy performance ,
(b) AS/NZS 4847.2(Int):2008, Self-ballasted lamps for general lighting services, Part 2: Minimum Energy Performance Standards (MEPS) requirements .
Note: This provision is subject to amendments to be made by the Energy and Utilities Administration Further Amendment (Minimum Energy Performance Standards) Regulation 2009 . These amendments commence on 1.10.2011.