NATIONAL MEASUREMENT REGULATIONS 1999 - SCHEDULE 6 Maximum permissible uncertainty--volume (State secondary and tertiary standards)
NATIONAL MEASUREMENT REGULATIONS 1999 - SCHEDULE 6
Maximum permissible uncertainty--volume (State secondary and tertiary standards)(paragraph 25 (c), subparagraph 25(d) (ii), paragraph 26(b) and subparagraph 26(c)(ii))
Column 1 Denomination | Column 2 Maximum permissible uncertainty (at 95% level of confidence): State secondary standard (in mL) | Column 3 Maximum permissible uncertainty (at 95% level of confidence): State tertiary standard (in mL) |
10 000 L | 750.000 | 1 500.000 |
5 000 L | 400.000 | 750.000 |
2 000 L | 150.000 | 300.000 |
1 000 L | 75.000 | 150.000 |
500 L | 40.000 | 75.000 |
200 L | 15.000 | 30.000 |
100 L | 8.000 | 15.000 |
50 L | 4.000 | 7.000 |
20 L | 1.500 | 4.000 |
15 L | 1.100 | 3.000 |
10 L | 0.800 | 2.000 |
5 L | 0.400 | 2.000 |
2 L | 0.200 | 1.000 |
1 L | 0.100 | 0.500 |
500 mL | 0.040 | 0.300 |
250 mL | 0.020 | 0.200 |
200 mL | 0.020 | 0.170 |
100 mL | 0.010 | 0.110 |
50 mL | 0.004 | 0.070 |
25 mL | 0.004 | 0.050 |
20 mL | 0.004 | 0.040 |
10 mL | 0.004 | 0.020 |
5 mL | 0.004 | 0.020 |
2 mL | 0.004 | 0.010 |
1 mL | 0.002 | 0.003 |
0.5 mL | 0.001 | 0.002 |
0.2 mL | 0.001 | 0.002 |
0.1 mL | 0.001 | 0.002 |