NAVIGATION (FIRE APPLIANCES) REGULATIONS 1968 - REG 11
Fire detection and fire alarm system
- (1)
- A ship shall be furnished with manually operated fire alarms fitted
throughout the passenger spaces and crew spaces in the ship for the purpose of
enabling a member of a fire patrol or any other person to give the alarm
immediately on the detection of fire.
- (1A)
- A fire alarm fitted in a ship in accordance with subregulation
- (1)
- shall,
when operated, activate aural and visual fire indicators on the navigating
bridge or in a fire control station.
- (2)
- A ship shall be furnished with an approved automatic fire detection and
fire alarm system capable of:
- (a)
- detecting the presence of fire in a part
of the ship that is inaccessible to members of a fire patrol; and
- (b)
- relaying the fact referred to in paragraph (a) to aural and visual fire
indicators on the navigating bridge or in a fire control station.
- (4)
- Where a fire detection and fire alarm system depends on electricity for
its operation, the system shall be connected to 2 sources of supply, one of
which shall be an emergency source.