BUILDING REGULATIONS(AMENDMENT) (NO. 33 OF 1992) - TABLE OF PROVISIONS 1. Commencement 2. After regulation 2 of the Building Regulations the following regulation is inserted: BUILDING REGULATIONS(AMENDMENT) (NO. 33 OF 1992) - REG 1 Commencement 1. These Regulations commence on the day on which section 4 of the Building (Amendment) Act 1992 commences. Insertion BUILDING REGULATIONS(AMENDMENT) (NO. 33 OF 1992) - REG 2 2. After regulation 2 of the Building Regulations the following regulation is inserted: Prescribed buildings "3. (1) For the purposes of section 6AA of the Act, each of the following buildings is a prescribed building: (a) a fence or wall that-- (i) does not exceed 1.8 metres in height; and (ii) does not form an integral part of an enclosure for a swimming pool; (b) a retaining wall the top of which does not exceed 1.2 metres above the lower ground level; (c) a carport or, subject to subregulation (2), a pergola-- (i) the plan area of which does not exceed 25 square metres; (ii) the height of which does not exceed 3 metres; (iii) the distance between any 2 adjacent supports of which does not exceed 4 metres; and (iv) where it is attached to an approved building--that does not project above the line of any adjacent guttering on that building; (d) a shed, gazebo, greenhouse or similar structure the roof area of which does not exceed 10 square metres; (e) an external timber deck the height of the floor level of which does not exceed 1 metre above ground level; (f) an antenna or aerial not exceeding 5 metres in height; (g) a swimming pool the capacity of which does not exceed 10 cubic metres and designed to be assembled and installed above ground level; (h) an internal alteration to an approved building the effect of which does not alter the classification of the building; (j) an outdoor ornamental pond the depth of which does not exceed 300 millimetres; (k) a barbeque, letterbox, or other structure, having a plan area not exceeding 2 square metres and which is not more than 1.8 metres high; (m) a water tank-- (i) having a capacity not exceeding 17 kilolitres; (ii) the top of which is not more than 2.4 metres above ground level; and (iii) that is not connected to the water supply of the Electricity and Water Authority. "(2) Subparagraph (1) (c) (i) applies to a roofed pergola. "(3) Subregulation (1) does not apply if-- (a) the building work in respect of the prescribed building affects-- (i) the structural sufficiency, soundness or stability of part of any approved building; (ii) a fire rated wall, ceiling or floor; (iii) any ventilation or air-handling system, fire protection system or other mechanical service; or (iv) any fire escape, emergency lift, stairway, exit or passageway to an exit; or (b) the building proposed to be built adversely affects the provision of natural light or ventilation to any approved building.". BUILDING REGULATIONS(AMENDMENT) (NO. 33 OF 1992) - NOTES NOTE 1. Reprinted as at 30 September 1991. 2. Notified in the ACT Gazette on 11 December 1992. (c) Australian Capital Territory 2003 BUILDING REGULATIONS(AMENDMENT) (NO. 33 OF 1992) - NOTES AUSTRALIAN CAPITAL TERRITORY The Australian Capital Territory Executive makes the following Regulations under the Building Act 1972. Dated 7 December 1992. TERRY CONNOLLYMinister BILL WOODMinister